Caratteristiche centralina e sensori per acquisizione dati - Stazione di URBINO
 

Immagine

Componente Modello Caratteristiche

Centralina CR-10
Campbell
 

Interfaccia SC32A - RS232 Interface
Campbell
Optoisolata
  Modem DC112 Modem
Campbell
 
Webcam

MOMX-M22M-SEC-D22
Mobotix

 

Temperatura e umidità MP103A
Rotronic
Power: 4.8..30VDC - Op. range: 0..100% RH -40 +60 °C - Out H: 0-100% 0-1V - Out T: -40 +60 °C 0-1V

 

Pressione BHL4240
Campbell
 

Precipitazione FSS1000H Collector area: 500 cm2. Overall Height: 370 mm. Output: Contact closure at tip (two reed switches providing two independent data channels). Tip sensitivity: 0.1 mm. Cable: 6 m. Weight: 6 kg

Forza del Vento C100S Cup tacho-anemometer
Lastem
Wind speed measurement with opto-electronic system - Measurement range: 0-50 m/sec - Tolerance: 1% - Resolution: 0.1 m/sec - Threshold: 0.25 m/sec - Delay distance: 4.5 m - Linearity: 0.5% - Amb. temp. limits: -35 +60 °C - Material: light alloy coated with polyurethane paint - External measurements: height (167 mm) Ø 466 mm - Weight: 720 g

Direzione del Vento C100D Gonio-anemometer
Lastem
Wind direction measurement with potentiometric system - Measurement range: 0-355° - Resolution: infinite - Sensor: potentiometer 0-2 KOhm - Tolerance: 3% - Threshold: 0.3 m/sec - Linearuty: 0.5% - Damping rate: 0.4 - Wave lenght: 3.5 m - Delay distance: 1.1 m - Amb. temp. limits: -35 +60 °C - Material: light alloy coated with polyurethane paint - External measurements: height (200 mm) Ø 520 mm - Weight: 870 g
Radiazione solare C110R Total radiometer
Lastem

Measurement principle: thermopile - Spectral sensitivity: 0.3...3 µm - Sensitivity: 15 µV/Wm-2

 
 

Ultima modifica effettuata il 30 giugno 2011 da Piero Paolucci