Caratteristiche centralina e sensori per acquisizione dati - Stazione del CAMPUS SCIENTIFICO ex SOGESTA
 
Immagine Componente Modello Caratteristiche
cr510.jpg (4843 byte) Centralina CR-510 Campbell Basic datalogger. Number of channels: 2 differential or 4 single-ended, individually configured; Size: (21.3 cm x 3.8 cm x 9.9 cm; Weight: 425 g.
sc32a.jpg (2837 byte) Interfaccia SC32A - RS232 Interface Campbell Optoisolata. Operating temperature -25 °C to +50 °C. Size/Weight: 130 x 60 x 25mm, 0.1 kg
mp103a.jpg (80914 byte) Temperatura e umidità MP103A Rotronic + SS2 schermo a ventilazione naturale Environmental Power: 4.8..30VDC - Op. range: 0..100% RH -40 +60 °C - Out H: 0-100% 0-1V - Out T: -40 +60 °C 0-1V
vaisala.jpg (23700 byte) Pressione PTB101B Vaisala Analog barometer. Operating range: 600 mB to 1060 mB (hPa); Temperature range: -40°C to +60°C; Humidity range: non-condensing; Size: 59mm x 97mm x 21mm; Weight: 130 g.
arg100.jpg (37906 byte) Precipitazione ARG100 Environmental Aerodynamic raingauge. Funnel diameter: 254 mm; Overall height 340 mm; Tip sensitivity: standard setting 0.20 mm of rain per tip. Output: contact closure at tip; Cable 10 m; Weight 1.0 Kg
young1.jpg (16783 byte) Direzione del Vento 3002 Young
Range: 360° mechanical, 355° electrical (5° open)
Sensor: Balance vane, 16 cm turning radius
Accuracy:  ±5°
Damping Ratio: 0.2
Delay distance (50% recovery): 0.5 m (1.6 ft)
Threshold: 0.8 m s-1 (1.8 mph) at 10° displacement - 1.8 m s-1 (4 mph) at 5° displacement
Vane lenght: 22 cm (8.7 in)
Vane weight: 170 g (6 oz)
young1.jpg (16783 byte) Velocità del Vento 3002 Young
Range: 0 to 50 m s-1 (112 mph), gust survival 60 m s-1 (134 mph)
Sensor: 12 cm diameter cup wheel assembly, 40 mm diameter hemispherical cups
Accuracy: ±0.5 m s-1 (1.1 mph)
Turning factor: 75 cm (2.5 ft)
Distance constant (63% recovery): 2.3 m (7.5 ft)
Threshold: 0.5 m s-1 (1.1 mph)
Cup wheel diameter: 12 cm (4.7 in)
Weight: 113 g (4 oz)
 
 

Ultima modifica effettuata il 30 giugno 2011 da Piero Paolucci

ossmeteo@uniurb.it